Inductive Fault Current Limiters

50% reduction of fault currents, ¼ cycle reaction time,
handles long duration faults and breaker reclosure attempts

 

Fault tolerance is an increasingly important issue in power grid operation. Zenergy Power’s Fault Current Limiters protect power grids against damaging power surges caused by short circuits or lightning strikes while maintaining a disruption-free downstream power supply. Inductive Fault Current Limiters provide power grid operators with a new solution for grid reliability, cost-efficient grid expansion, and integration of distributed generation sources.

 

  • Inherently failsafe inductive limitation of fault currents without interruption in downstream power supply;
  • Entirely passive and self-triggered
  • Failsafe limitation of multiple faults; automatic recovery after each event
  • Improved operational reliability in fully-stretched grids;
  • Greatly reduced risk of large scale blackout due to cascading grid failures following a fault event
  • Standard solution for cost-efficient grid expansion;
  • Deferred replacement of substation equipment
  • Simplified integration of distributed power generation into the network infrastructure.

 

Zenergy Power’s Fault Current Limiter has been put into regular operation in the United States’ power grid in March 2009. Southern California Edison is the first electric utility company in the US to use the device for protecting a distribution circuit of its medium voltage grid.

 

There are no translations available.

fcl-1.jpgfcl-2.jpgfcl-3.jpgfcl-4.jpg



More Information

Contact

  • Zenergy Power GmbH
    Dr. Jürgen Kellers
    Heisenbergstr. 16
    53359 Rheinbach
    Germany
  • Phone: +49 (2226) 9060 602
  • Fax: +49 (2226) 9060 900
  • This e-mail address is being protected from spambots. You need JavaScript enabled to view it
  • Vcard: Dr. Jürgen Kellers
  • Zenergy Power Inc.
    Dr. Larry Masur
    379 Oyster Point Blvd, Suite 1
    South San Francisco, CA 94080
    USA
  • Phone: +1 (650) 615 5700
  • Fax: +1 (650) 615 5705
  • This e-mail address is being protected from spambots. You need JavaScript enabled to view it
  • Vcard Dr. Larry Masur
  • Zenergy Power Pty Ltd.
    John Khoury
    Suite 7, 1 Lowden Square
    Wollongong   NSW   2500
    Australia
  • Phone: +61 2 4227 6611
  • Fax: +61 2 4227 6644
  • This e-mail address is being protected from spambots. You need JavaScript enabled to view it
  • Vcard: John Khoury